To learn more about the software which generates this data, please visit K8CU at:

www.realhamradio.com

Status Updates:

23 JAN 2011: For some reason, the receiver is now failing Self Test. Occasionally, it will report that the 15VDC line is out of limits, even though I measure +15.2VDC at the +15V test point! Don't know what to make of all this.


Power-on time
Days---Hrs---Mins-Secs
           HEWLETT-PACKARD,Z3801A,3542A05735,3543-A. Life count: 34767
SYNCHRONIZATION ............................................. [ Outputs Valid ]
SmartClock Mode ___________________________   Reference Outputs _______________
>> Locked to GPS                              TFOM     3             FFOM     0
   Recovery                                   1PPS TI +56.4 ns relative to GPS
   Holdover                                   HOLD THR 1.000 us
   Power-up                                   Holdover Uncertainty ____________
                                              Predict  3.8 us/initial 24 hrs
                                                
ACQUISITION ............................................ [ GPS 1PPS CLK Valid ]
Satellite Status __________________________   Time ____________________________
Tracking: 6        Not Tracking: 2            UTC      11:09:26     28 Jan 2012
PRN  El  Az   SS   PRN  El  Az                1PPS CLK Synchronized to UTC
  2  24 224  151     9  24 301                ANT DLY  0 ns
  4  59 221  105    10  15 166                Position ________________________
 17  60  23  120                              MODE     Hold
 20  25  64   66                              
 27  33 282  102                              LAT      N  34:51:11.215
 28  57 125   81                              LON      W  86:44:02.317
ELEV MASK 10 deg                              HGT              +273.16 m  (MSL)
HEALTH MONITOR ...................................................... [ ERROR ]
Self Test: Err   Int Pwr: OK   Oven Pwr: OK   OCXO: OK   EFC: OK   GPS Rcv: OK